BS IEC 62047-41:2021 pdf download

BS IEC 62047-41:2021 pdf download.Semiconductor devices - Micro-electromechanical devices
1 Scope
This part of IEC 62047 specifies the terminology, essential ratings and characteristics, and measuring methods of RF (Radio Frequency) MEMS (Micro-Electro-Mechanical Systems) circulators and isolators.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60747-1:2010, Semiconductor devices - Part 1: General
IEC 60749-10, Semiconductor devices一Mechanical and climatic test methods一Part 10:Mechanical shock
IEC 60749-12,Semiconductor devices一Mechanical and climatic test methods - Part 12:Vibration, variable frequency
IEC 60749-21,Semiconductor devices一Mechanical and climatic test methods一Part 21:Solderability
IEC 60749-22,Semiconductor devices - Mechanical and climatic test methods - Part 22:Bond strength
IEC 62047-1, Semiconductor devices - Micro-electromechanical devices- Part 1: Terms and definitions
IEC TS 61967-3, Integrated circuits 一Measurement of electromagnetic emissions 一Part 3:Measurement of radiated emissions一Surface scan method
3.1.1 circulator
three-port device in which the incident wave to any port is transmitted to the next port according to an order of sequence determined by the sense of a static magnetic biasing field
Note 1 to entry:By reversing the magnetic biasing field, the order of sequence is reversed.
Note 2 to entry:This property may be used to switch electromagnetic waves.[SOURCE: IEC 60050-726:1982,726-17-08, modified - The word“multiport" is replaced by "three-port"]
3.1.2 isolator
two-port device having much greater attenuation in one direction of propagation than in the opposite direction[SOURCE: IEC 60050-726:1982, 726-17-19]
3.2 RF characteristics parameters
3.2.1 insertion loss
Lins
resulting from the insertion of a network into a transmission system, the ratio of the power delivered to that part of the system following the network, before insertion of the network, to the power delivered to that same part after insertion of the network Note 1 to entry: The insertion loss is generally expressed in decibels.[SOURCE: IEC 60050-726:1982, 726-06-07]
4.1 ldentification and types
General description of the function of the RF MEMS circulator/isolator and their applications should be stated. The statement should include the details of manufacturing technologies about the RF MEMS circulator/isolator with different operation, configuration, and actuation mechanism. The statement should also include packaged form including terminal numbering and package materials.
The RF MEMS circulator/isolator shall be clearly and durably marked in the order given below:
a) manufacture's name or trade mark;
b) device type and serial number;
c) year and week (or month) of manufacture;
d) terminal identification (optional);
e) factory identification code (optional).
4.2 Application and specification description
Information on application of the RF MEMS circulator/isolator shall be given. Block diagrams of the RF MEMS circulator/isolator and the applied systems should be also given. AII terminals should be identified in the block diagram and their functions shall also be stated.BS IEC 62047-41 pdf download.