EN IEC 62275:2019 pdf download

EN IEC 62275:2019 pdf download.Cable management systems - Cable ties for electrical installations (IEC 62275:2018)
5.1 Tests according to this document are type tests. Unless otherwise specified, tests are carried out with the cable ties and their associated fixing devices, where available, installed as in normal use according to the manufacturer's instructions.
Unless otherwise specified, requirements and tests for fixing devices also apply to adhesive fixing devices.
NOTE For guidance in determining product types and sample sets, a family of cable ties or fixing devices having material, construction characteristics, and classifications according to Clause 6, in common, are considered of the same product type. Examples for consideration are identical generic material description, material colours, or variable lengths of a cable tie of otherwise similar construction. The sample sets selected for testing from each product type is representative of the extremes of the range (example: shortest and longest), and the minimum performance level obtained for either extreme is determined to be representative of the entire range.
5.4 Unless otherwise specified, three new samples are submitted to the tests and the requirements are satisfied if all the tests are met. If only one of the samples does not satisfy a test owing to an assembly or manufacturing fault, that test and any preceding one which may have influenced the results of the test shall be repeated. The tests that follow shall be carried out in the required sequence on another full set of samples, all of which shall comply with the requirements.
NOTE The applicant, when submitting the first set of samples, can also submit an additional set of samples which may be necessary if one sample fails. The test station will then without further request test the additional set of samples and will reject only if a further failure occurs. If the additional set of samples is not submitted at the same time, a failure of one sample will entail a rejection.
5.8 An integral assembly shall be tested as a complete sample. The integral assembly shall be subjected to the conditionings for the cable tie prior to conducting the mechanical strength test for the fixing device in accordance with 9.7.
A fixing device, the performance of which is dependent on the mounting hole size, the thickness of the material sheet to which it is to be mounted, or the mounting orientation declared by the manufacturer in accordance with Table 7, shall comply with all applicable tests when the device is assembled to the minimum and maximum thickness of each mounting surface, in the largest hole size, and in each intended mounting orientation declared by the manufacturer. When it can be determined that a particular mounting orientation represents the most onerous condition, the results of the tests in that orientation may represent all mounting orientations. EN IEC 62275 pdf download.