IEC 60884-3-1:2021 pdf download

IEC 60884-3-1:2021 pdf download.Plugs and socket-outlets for household and similar purposes
1 Scope
IEC 60884-1:-,Clause 1 is applicable except as follows:
Replace the first paragraph by the following:
This part of IEC 60884 applies to fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors, incorporating a USB power supply.
This document defines the safety and EMC requirements for socket-outlets incorporating a USB power supply.
Specifications, performance and dimensional requirements of the USB technologies are not covered by this document; these are defined in the relevant part(s) of IEC 62680.
2 Normative references
IEC 60884-1:-, Clause 2 is applicable except as follows:
Addition:
IEC 60317-0-1:2013, Specifications for particular types of winding wires - Part 0-1: General requirements一Enamelled round copper wire
IEC 60317-0-1:2013/AMD1:2019
IEC 60884-1:-2, Plugs and socket-outlets for household and similar purposes - Part 1: General requirements
IEC 61000-3-2,Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current S16 A per phase)
IEC 61000-4-2,Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3,Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4,Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5,Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6,Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8,Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11, Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques一Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 62368-1:2018, Audio/video, information and communication technology equipment- Part 1:Safety requirements
IEC 62368-3:2017, Audio/video, information and communication technology equipment- Part 3: Safety aspects for DC power transfer through communication cables and ports
CISPR 32, Electromagnetic compatibility of multimedia equipment一Emission requirements
13.101 Conductors used in a USB power supply
Internal wiring that is accessible during and/or after installation, if any, shall be secured in such a way that it cannot become loose or detached and impair the safety of the accessory.
Conductor terminations using solder shall be mechanically secured. Hooking the conductor through a hole of the conductive termination and affixing conductors in thermal tubing, sealing compound or glue are examples of acceptable securement.
This requirement is not applicable to internal wiring that cannot be so displaced such that clearances or creepage distances are reduced below the specified values or such that, if it becomes loose, it cannot create hazardous connections between primary and secondary circuits.IEC 60884-3-1 pdf download.

Download
Download

匿名

Comment

Anonymous