UL 464A:2021 pdf download

UL 464A:2021 pdf download.STANDARD FOR SAFETY-Audible Signal Appliances for General Signaling Use.
1.1 These requirements cover electrically and electronically operated bells, buzzers, horns, and similar audible signal appliances, rated 300 volts or less, for commercial general signaling service and intended for indoor or outdoor locations or both in accordance with the National Electrical Code, NFPA 70.
1.2 These requirements cover audible signal appliances for use in ordinary locations. Audible signal appliances for use in hazardous locations, as defined in the National Electrical Code, NFPA 70, are judged on the basis of their compliance with these requirements and further appropriate examination and tests to determine if they are acceptable for such use.
1.3 These requirements do not cover door bells, buzzers, and chimes used in household and similar applications and intended for operation on Class 2 signal circuits as defined in the National Electrical Code, NFPA 70.
1.4 These requirements do not cover audible signaling appliances intended for fire alarm or emergency communications use as defined by the National Fire Alarm and Signaling Code, NFPA 72.
1.5 A supplemental visual signal incorporated as part of an audible signal appliance shall also comply with the requirements of this Standard.
CONSTRUCTION
2 General
2.1 Components
2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard.
2.1.2 A component is not required to comply with a specific requirement that:
a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or
b) Is superseded by a requirement in this standard.
2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use.
2.1.4 Specific components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specified limits, and shall be used only under those specific conditions.
2.2 Units of measurement
2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information.UL 464A pdf download.