CSA 2.41:2017 pdf download

CSA 2.41:2017 pdf download.Outdoor decorative gas appliances
1.1 CSA 2.41 applies to newly produced decorative gas appliances for outdoor installation (see Clause 3, Definitions), constructed entirely of new, unused parts and materials; hereinafter referred to as "appliance." Appliances submitted for examination under this Standard are classified as one of the following: portable, stationary, or built-in.
1.2 Appliances may be for:
a) connection to a fixed fuel piping system; or
b) connection to a self-contained propane gas supply system (see Clause 3, Definitions). Cylinder(s) for a self-contained system may be either remote to the appliance or integrally mounted on the appliance, are designed for vapor withdrawal only.
i) Appliances with input ratings less than 60,000 Btu/hr (17 584 W) are designed to accommodate a vertically mounted integral cylinder with a maximum size of 20 Ib (9.1 kg) of fuel.
ii) Appliances with input ratings greater than or equal to 60,000 Btu/hr (17 584 W) may be designed to accommodate a vertically mounted integral cylinder with a maximum size of 30 Ib (13.6 kg) of fuel.
iii) Appliances with input ratings greater than or equal to 80,000 Btu/hr (23 446 W) may be designed for not more than two vertically mounted integral vapor withdrawal cylinders, each with a maximum size of 20 lb (9.1 kg) of fuel.
iv) Portable appliances intended for table top use are to have input ratings limited to not more than 15,000 Btu/hr (4 396 W), and are designed to accommodate a vertically mounted cylinder with a maximum size of 16.4 oz (465 g) of fuel.
v) Portable appliances with input ratings not greater than or equal to 25,000 Btu/hr (7 327 W) may be designed for the use of not more than two cylinders, each with a maximum size of 16.4 oz (465 g) of fuel.
vi) Appliances designed for use with remote propane cylinders are limited to one cylinder of maximum 30 Ib (13.6 kg) of fuel or two cylinders with maximum of 20 Ib (9.1 kg) of fuel each.
1.5 This Standard also applies to appliances designed for connection to self-contained propane gas supply systems:
a) operating at regulated outlet pressures not to exceed 11 in wc (2.74 kPa); or
b) operating at regulated outlet pressures in excess of 11 in WC (2.74 kPa) but not greater than 5 psi (34.5kPa).
1.6 Built-in appliances may be for:
a) connection to a fixed fuel piping system; or
b) connection to a remote self-contained propane gas supply system (see Clause 3, Definitions),provided the appliance is supplied with remote mounting and retention means for the attachment of a single cylinder with a maximum size in accordance with Clause 1.2b)i) or Clause 1.2b)i) and instructions for installing the mounting and retention means within the built-in enclosure.CSA 2.41 pdf download.