CSA A277-16:2018 pdf download

CSA A277-16:2018 pdf download.Procedure for certification of prefabricated buildings, modules, and panels
2 Reference publications
CSA A277-16 refers to the following publications. Where such reference is made and the publication is in force in the jurisdiction where the building will be placed for occupancy, it shall be to the edition and all amendments in force at the installation location at the time of construction. Where such reference is made and the publication is not in force at the installation location, the reference shall be to the edition listed below, including all amendments thereto.
Note: See also Clause 4 (Clause 4 refers to codes or regulations in force, not in force, etc.).
4.1.1 Codes or regulations in force
Where codes or other regulations addressing building design and construction are in force at the installation location, prefabricated buildings, prefabricated modules, and prefabricated panels shall be designed and constructed to comply with those codes and regulations as applicable.
4.1.2 Codes or regulations not in force
Where codes or other regulations are not in force at the installation location to address some or all aspects of building design and construction, prefabricated buildings, prefabricated modules, and prefabricated panels shall be designed and constructed to comply, as applicable, with the following:
a) the National Building Code of Canada or the CSA Z240 MH Series;
b) the Canadian Electrical Code, Part 1, for the installation of electrical systems;
c) the National Plumbing Code of Canada, for factory-installed plumbing and fixtures; and
d) the National Energy Code for Buildings.
4.2 Administrative requirements
Design, design review, and construction review shall be carried out by qualified persons, and stamped detail drawings and other documentation shall be provided as required by the regulations that apply at the location where the building is to be installed. (See Annex A.)
Notes:
1) This requirement applies in addition to the requirements for inspection and auditing by the certification body.
2) Requirements for involvement by architects, engineers, or other qualified persons vary by jurisdiction. Involvement by architects or engineers generally relates to building occupancy (use) and size. Stamped detail drawings might be required for structural, electrical, plumbing, mechanical, gas, and life safety systems.
3) Other required documentation can include, for example, letters of assurance or letters of undertaking.
5 Certification requirements
Certification shall be conducted by an accredited certification body recognized by the authority having jurisdiction and shall include
a) certification of the manufacturer's quality system and quality program in accordance with requirements specified by the certification body; and
b) certification of prefabricated buildings, modules, or panels as complying with, as applicable
i) regulations in force at the installation location or as described in Clause 4.1.1; and
ii) regulations in force at the installation location with respect to involvement of qualified persons as described in Clause 4.1.2.CSA A277-16 pdf download.

Download
Download

匿名

Comment

Anonymous