1 Scope
This document gives specifications for single- and double-conductor secondary connection cables used for resistance welding and allied processes. These specifications include requirements for electrical,mechanical and cooling characteristics of the cables and their test procedures.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
一ISO Online browsing platform: available at https://www.iso.org/obp
一IEC Electropedia: available at http://www.electropedia.org/
3.1 double-conductor connection cable
cable comprising two conductors providing an electrical link between the secondary terminals of a welding transformer and the welding set (manual or robotized guns) and designed so as to have as low an electrical reactance as possible
3.2 single-conductor connection cable
cable comprising one conductor providing an electrical link between the secondary terminals of a welding transformer and the welding set (manual or robotized guns)
4 Classification
4.1 Form of the end lugs
Double-conductor water-cooled connection cables are classified into two types, A-1 and A-2, in accordance with the form of the end lugs (see 5.1.3).
Single-conductor water-cooled connection cables are classified into three types, C-1, C-2 and D, in accordance with the form of the end lugs (see 5.2.3).
4.2 Resistance and reactance
Double-conductor, water cooled connection cables are classified into two types, A-1 and A-2, with power factor cosp≥0,95 as shown in Figure 1.
5 Dimensions
5.1 Double conductor connection cables
5.1.1 Cross-sectional area
The effective cross-sectional area of copper per conductor shall be one of the following:
一100 mm2
一150 mm2
一160 mm2
一200 mm2
一250 mm2
一315 mm2
5.1.2 Length
The length, L, of the cable shall be one of the following (non-preferred values are given in parentheses).
The length shall have a tolerance 1/0 %:
一1 000 mm
一1200mm
一1250mm-(1500mm)
一1600mm-(1800mm)
一2 000 mm- (2 240 mm)
一2400mm
一2500mm-(2800mm)
一3 000 mm
一3150mm
一3500mm-(3550mm)
一4 000 mm
5.1.3 End lugs
The end lugs shall have the dimensions given in Figure 1 and Table 1.
5.2 Single conductor connection cables
5.2.1 Cross-sectional area
The effective cross-sectional area of copper per conductor shall be one of the following:
一150 mm2
一160 mm2
一180 mm2
一200 mm2
一250 mm2
一315 mm2
5.2.2 Length
The length, L, of the cable shall be one of the following (non-preferred values are given in parentheses).
The length shall have a tolerance 1/0 %:
一500 mm
一630 mm
一800 mm
一1 000 mm
一1250mm-(1500mm)
一1600mm-(1800mm)ISO 8205 pdf download.